Non-Fiction Books:

Control of Distribution System Water Quality Using Inhibitors

Sorry, this product is not currently available to order

Here are some other products you might consider...

Control of Distribution System Water Quality Using Inhibitors

Click to share your rating 0 ratings (0.0/5.0 average) Thanks for your vote!
Unavailable
Sorry, this product is not currently available to order

Description

Tampa Bay Water (TBW) manages a number of city and county drinking water resources and has recently had to use finished waters produced from saline and surface water sources to supplement their groundwater supplies. Drinking water utilities in Florida and similar environments have historically relied on groundwater, but overreliance on the source has led to the pursuit of other multiple sources. Finished water quality varies by source and the effects of corrosion inhibitors on distribution water quality are unknown. Hence, the capabilities of corrosion inhibitors to offset the adverse effects of changing finished water quality on distribution system water quality needs to be investigated. This study was conducted to investigate the capabilities of corrosion inhibitors (orthophosphate (OP), zinc orthophosphate (ZOP), blended ortho-polyphosphate (BOP), silicate, or pH only inhibition) to offset the adverse effects of changing finished water quality on distribution system water quality. Eighteen PDS's and two pilot treatment systems were used for this project. The 14 hybrid PDS's from four different pipe materials were used for the inhibitor study while the other four single material lines were used to investigate the effect of turbulence on chloramine decay. Twelve thousand gallons of conventionally treated groundwater and desalinated groundwater from the two pilot processes on site and from the TBW regional surface water treatment plant were used each week. Water was blended at predetermined ratios and distributed to the PDS's. BOP, OP, ZOP, silicate inhibitors, and NaOH (pH only) were added to the PDS's. Phosphate inhibitors were dosed at 0.5, 1, and 2 mg/L as P; silicate inhibitors were dosed at 3, 6, and 12 mg/L as SiO2; and two PDS's were maintained at pHs and pHs+0.3. Physical, chemical, and biological changes were monitored throughout the PDS's. This work has shown that inhibitor addition was necessary to control Fe, Cu, and Pb release in high alkalinity finished water and provide a higher water quality to consumers. Models relating EN to Fe, Cu, and Pb release predicted metal release as accurate, less costly, and more rapid than water quality models. Inhibition addition did not affect chloramine residual but was shown to increase biological activity in distribution systems.
Release date Australia
September 1st, 2009
Audiences
  • Professional & Vocational
  • Tertiary Education (US: College)
Country of Publication
United Kingdom
Imprint
IWA Publishing
Pages
476
Publisher
IWA Publishing
Dimensions
156x234x18
ISBN-13
9781843392613
Product ID
6103265

Customer reviews

Nobody has reviewed this product yet. You could be the first!

Write a Review

Marketplace listings

There are no Marketplace listings available for this product currently.
Already own it? Create a free listing and pay just 9% commission when it sells!

Sell Yours Here

Help & options

Filed under...